Filling machine maintenance knowledge
Jan 09, 2023
The filling machine cannot be started
1. Turn on the power, turn on the power switch, and check the fuse.
2. Release the emergency stop button.
3. Turn on the air pressure and keep it around 6kg.
4. Check whether the switching power supply has DC24V power output.
5. Check whether the communication line between the touch screen and PLC is loose.
The filling machine does not produce material
1. Check the air pressure, check the touch screen maintenance method screen.
2. Whether the nozzle is closed, check the circuit.
3. Add materials.
4. Check the air pressure, check whether the injection cylinder and the injection cylinder are dead, check whether the discharge nozzle on the touch screen maintenance method screen is closed, and check the circuit.